"Battery for my APC SU620 worked perfectly, just as it should."I ordered the wrong item, (my fault) item was returned without any problems."."I just asked to recycle the old battery and they advised that it would be recycled by the store where I bought it.Stable voltage and broad temperature range: (-60° to +85☌) For battery cell replacement in Modicon AS-5284-001.
90 30 VERSAPRO PLC DISTRIBUTORS SERIES
Works With: Allen Bradley 1775, PLC-3 and Modicon 484, 584 series programmable logic controllers and industrial computers. Insufficient Circuits and Parts Can Result in a Possible Fire or Explosion in Some Cases.Ĭonnector Type: Wire Leads with Connector Please be Aware of Online Pirate Companies who Make Their Own Batteries with Insufficient Safety Circuits and Low Grade Materials. Only the Highest Grade of Materials are Used to Manufacture our Batteries, with Safety and Performance in Mind. (This is one Battery – Please verify quantity needed for your application before ordering)īatteryGuy PLC and Industrial Computer Batteries are Manufactured to Meet or Exceed the Quality of the Original Equipment Manufacturer. It meets or exceeds the General Electric Fanuc 90-30 PLC specifications defined by the Original Equipment Manufacturer but at a much lower price.

90 30 VERSAPRO PLC DISTRIBUTORS SOFTWARE
Incorrect communication settings in the software – The default settings for the Series 90 CPU programming port is 19200 BAUD, 8 data bits, 1 stop bit and odd parity.
90 30 VERSAPRO PLC DISTRIBUTORS SERIAL
How do I identify the cause?īad port on the PC – Try using the PC’s serial port to communicate to another device in order to confirm proper operationīad cable – Try connecting to another Series 90 PLC in order to confirm the condition of the cable. Series 90-30 Series 90-70 HMI Up to 16 devices without repeaters Serial I/O can be used to Initialize either port. Only do this when passwords are not a concern.
90 30 VERSAPRO PLC DISTRIBUTORS DOWNLOAD
Once the memory is erased, a configuration with passwords enabled can be downloaded to the CPU.Īn alternative solution would be to change the configuration being downloaded to a “Passwords Disabled” setting and then download the configuration to the CPU. In certain cases with the Series 90-30 CPUs, you may have to clear the memory by shorting out a super-capacitor on the CPU module by removing the CPU from the baseplate and shorting across two solder pads labeled “MEM CLR” for about 10 seconds. This can be done by powering down the CPU, disconnecting the battery, and powering up the CPU with the battery still disconnected. This error occurs when the user tries to download a configuration where the CPU is configured for “Passwords Enabled” and the CPU being downloaded to is set for “Passwords Disabled.” Once passwords are disabled in a Series 90 CPU, the only way to download a configuration where the CPU is configured for “Passwords Enabled” is to completely erase the memory in the target CPU. When I try to download the configuration to my Series 90 CPU, the download fails because passwords are disabled. To learn about these programming options, click here. This is the only software that will support new Series 90-30 and VersaMax CPUs and modules as they come out. Enhancements to this software are on-going.
90 30 VERSAPRO PLC DISTRIBUTORS PLUS
It supports all of the same PLCs that VersaPro Standard can plus a number of newer Series 90-30 and VersaMax PLC that VersaPro Standard does not. This is the current software package for Series 90-30 PLCs. Proficy Machine Edition Logic Developer PLC Standard Edition – This is a Windows-based package and can run in Windows 2000, XP and Vista environments. In addition to the Series 90-30, VersaPro Standard can also program Series 90 Micros and certain VersaMax Micro and modular PLCs. It is not supported by GE Fanuc in the Windows Vista environment. VersaPro Standard Edition – This is a Windows-based package and can run in Windows 95, 98, 2000 and XP environments. This is a mature product, meaning no further enhancements are planned. It is not supported by GE Fanuc in Windows XP and Vista environments. It is DOS-based and can run in Windows 95, environments. Logicmaster 90-30 – This is the original software for the Series 90-30.

There are 3 software packages available for this purpose.